22 research outputs found

    Carrier and Light Trapping in Graded Quantum Well Laser Structures

    Full text link
    We investigated the carrier and light trapping in GaInAs/AlGaAs single quantum well laser structures by means of time resolved photoluminescence and Raman spectroscopy. The influence of the shape and depth of the confinement potential and of the cavity geometry was studied by using different AlGaAs/GaAs short-period superlattices as barriers. Our results show that grading the optical cavity improves considerably both carrier and light trapping in the quantum well, and that the trapping efficiency is enhanced by increasing the graded confining potential.Comment: PDF-format, 15 pages (including 4 figures), Applied Physics Letters (June 2000

    High efficacy of Sofosbuvir plus Simeprevir in a large cohort of Spanish cirrhotic patients infected with genotypes 1 and 4

    Get PDF
    [Abstract] Background and Aims. Hepatitis C (HCV) therapy with Sofosbuvir (SOF)/Simeprevir (SMV) in clinical trials and real‐world clinical practice, showed high rates of sustained virological response (SVR) in non‐cirrhotic genotype (GT)‐1 and GT‐4 patients. These results were slightly lower in cirrhotic patients. We investigated real‐life effectiveness and safety of SOF/SMV with or without ribavirin (RBV) in a large cohort of cirrhotic patients. Methods. This collaborative multicentre study included data from 968 patients with cirrhosis infected with HCV‐GT1 or 4, treated with SOF/SMV±RBV in 30 centres across Spain between January‐2014 and December‐2015. Demographic, clinical, virological and safety data were analysed. Results. Overall SVR was 92.3%; the majority of patients were treated with RBV (62%) for 12 weeks (92.4%). No significant differences in SVR were observed between genotypes (GT1a:94.3%; GT1b:91.7%; GT4:91.1%). Those patients with more advanced liver disease (Child B/C, MELD≥10) or portal hypertension (platelet count≤100×109/L, transient elastography≥21 Kpa) showed significantly lower SVR rates (84.4%‐91.9%) than patients with less advanced liver disease (93.8%‐95.9%, P<.01 in all cases). In the multivariate analysis, the use of RBV, female gender, baseline albumin≥35 g/L, MELD<10 and lack of exposure to a triple therapy regimen were independent predictors of SVR (P<.05). Serious adverse events (SAEs) and SAE‐associated discontinuation events occurred in 5.9% and 2.6%. Conclusions. In this large cohort of cirrhotic patients managed in the real‐world setting in Spain, SOF/SMV±RBV yielded to excellent SVR rates, especially in patients with compensated liver cirrhosis. In addition, this combination showed to be safe, with low rates of SAEs and early discontinuations.Instituto de Salud Carlos III; PI15/0015

    Effectiveness of an mHealth intervention combining a smartphone app and smart band on body composition in an overweight and obese population: Randomized controlled trial (EVIDENT 3 study)

    Get PDF
    Background: Mobile health (mHealth) is currently among the supporting elements that may contribute to an improvement in health markers by helping people adopt healthier lifestyles. mHealth interventions have been widely reported to achieve greater weight loss than other approaches, but their effect on body composition remains unclear. Objective: This study aimed to assess the short-term (3 months) effectiveness of a mobile app and a smart band for losing weight and changing body composition in sedentary Spanish adults who are overweight or obese. Methods: A randomized controlled, multicenter clinical trial was conducted involving the participation of 440 subjects from primary care centers, with 231 subjects in the intervention group (IG; counselling with smartphone app and smart band) and 209 in the control group (CG; counselling only). Both groups were counselled about healthy diet and physical activity. For the 3-month intervention period, the IG was trained to use a smartphone app that involved self-monitoring and tailored feedback, as well as a smart band that recorded daily physical activity (Mi Band 2, Xiaomi). Body composition was measured using the InBody 230 bioimpedance device (InBody Co., Ltd), and physical activity was measured using the International Physical Activity Questionnaire. Results: The mHealth intervention produced a greater loss of body weight (–1.97 kg, 95% CI –2.39 to –1.54) relative to standard counselling at 3 months (–1.13 kg, 95% CI –1.56 to –0.69). Comparing groups, the IG achieved a weight loss of 0.84 kg more than the CG at 3 months. The IG showed a decrease in body fat mass (BFM; –1.84 kg, 95% CI –2.48 to –1.20), percentage of body fat (PBF; –1.22%, 95% CI –1.82% to 0.62%), and BMI (–0.77 kg/m2, 95% CI –0.96 to 0.57). No significant changes were observed in any of these parameters in men; among women, there was a significant decrease in BMI in the IG compared with the CG. When subjects were grouped according to baseline BMI, the overweight group experienced a change in BFM of –1.18 kg (95% CI –2.30 to –0.06) and BMI of –0.47 kg/m2 (95% CI –0.80 to –0.13), whereas the obese group only experienced a change in BMI of –0.53 kg/m2 (95% CI –0.86 to –0.19). When the data were analyzed according to physical activity, the moderate-vigorous physical activity group showed significant changes in BFM of –1.03 kg (95% CI –1.74 to –0.33), PBF of –0.76% (95% CI –1.32% to –0.20%), and BMI of –0.5 kg/m2 (95% CI –0.83 to –0.19). Conclusions: The results from this multicenter, randomized controlled clinical trial study show that compared with standard counselling alone, adding a self-reported app and a smart band obtained beneficial results in terms of weight loss and a reduction in BFM and PBF in female subjects with a BMI less than 30 kg/m2 and a moderate-vigorous physical activity level. Nevertheless, further studies are needed to ensure that this profile benefits more than others from this intervention and to investigate modifications of this intervention to achieve a global effect

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Higher order analytical approximate solutions to the nonlinear pendulum by He's homotopy method

    Get PDF
    A modified He's homotopy perturbation method is used to calculate the periodic solutions of a nonlinear pendulum. The method has been modified by truncating the infinite series corresponding to the first-order approximate solution and substituting a finite number of terms in the second-order linear differential equation. As can be seen, the modified homotopy perturbation method works very well for high values of the initial amplitude. Excellent agreement of the analytical approximate period with the exact period has been demonstrated not only for small but also for large amplitudes A (the relative error is less than 1% for A < 152°). Comparison of the result obtained using this method with the exact ones reveals that this modified method is very effective and convenient.This work was supported by the ‘Generalitat Valenciana’, Spain, under project GVPRE/ 2008/182
    corecore